- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources2
- Resource Type
-
0000000002000000
- More
- Availability
-
11
- Author / Contributor
- Filter by Author / Creator
-
-
Asp, Merrill (1)
-
Carroll, Bobby (1)
-
Gupta, Sarthak (1)
-
Janmey, Paul A (1)
-
Jutzeler, Elise (1)
-
Kerr, Katherine (1)
-
Kochanowski, Jakub (1)
-
Kochanowski, Jakub A (1)
-
Mollenkopf, Paul (1)
-
Patteson, Alison (1)
-
Purohit, Prashant K (1)
-
Ren, Yifei (1)
-
Song, Dawei (1)
-
Vining, Kyle H (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Fibrous biopolymer gels under compression lose volume by the flow of water through pores. Fluid flow and network deformation in the gel are non-uniform. A model accounting for buckling of fibers captures the observed deformation and flow patterns.more » « lessFree, publicly-accessible full text available March 26, 2026
-
Asp, Merrill; Jutzeler, Elise; Kochanowski, Jakub; Kerr, Katherine; Song, Dawei; Gupta, Sarthak; Carroll, Bobby; Patteson, Alison (, The Biophysicist)ABSTRACT Rheology and the study of viscoelastic materials are an integral part of engineering and the study of biophysical systems. Tissue rheology is even used in the study of cancer and other diseases. However, the cost of a rheometer is feasible only for colleges, universities, and research laboratories. Even if a rheometer can be purchased, it is bulky and delicately calibrated, limiting its usefulness to the laboratory itself. The design presented here is less than a tenth of the cost of a professional rheometer. The design is also portable, making it the ideal solution to introduce viscoelasticity to high school students as well as for use in the field for obtaining rheological data.more » « less
An official website of the United States government
